Autoclave testing after repair

A repaired sterilizer has to prove it works before it goes back into service. We run every unit through full cycles on the bench with temperature and pressure checked against its settings, and you get the record for your log.

Biological indicator vial in an incubator, changed indicator tape and a cycle printout next to an autoclave door

What we check before a unit leaves

  • Full cycles of the types you use, with chamber temperature and pressure checked against the unit's own settings.
  • Door seal, drying and the end-of-cycle venting.
  • Water level and fill on automatic units; vacuum performance on Class B units.
  • The cycle printout or data log, sent back with the unit.
After the unit is back: run a biological indicator on your first loads and log it. California dental offices test at least weekly (16 CCR §1005); body-art studios must test after any major repair and at least monthly. See spore testing in California.

What it does, what failed, what it costs

SymptomUsual causeWhat we doPrice
Failed spore test with no error on the screenChamber not reaching or holding sterilizing temperature: sensor drift, a weak heater, air trapped by a leak, overloadingTemperature and pressure logged through full cycles, fault traced and repaired, retestedfrom $125
Indicator strips not changing fullyLow temperature, short exposure time, wrong cycle for the load, or wet packsCycle verified against the unit settings, cause found and quotedfrom $125
Unit back from a repair elsewhere, no paperworkRepair not documentedFull cycles with a logged temperature and pressure check, printout for your filefrom $125

Prices are "from", with labor, ordinary parts and a test cycle. The final price comes after the bench diagnostic, and nothing is done until you approve it. All prices →

What the price includes

  • Pickup and return anywhere in our Southern California area, the bench diagnostic and a written quote — $125, credited toward the repair.
  • After the repair: full cycles on the bench with a temperature and pressure check, the printout or log kept for your records.
  • A loaner on the same stop if you need one — from $149, free on repairs over $900.
  • 90-day warranty on repairs, 1 year on overhauls.

Questions

Do you spore-test the unit after a repair?

We run full cycles on the bench with chamber temperature and pressure checked against the unit settings, and we include the printout. The biological indicator that counts for your log is the one you run in your own office on your first loads back — the CDC recommends confirming a sterilizer with biological indicators after a major repair before it returns to use.

What does the CDC say to do after a major repair?

Run biological indicators in three consecutive empty cycles, and on pre-vacuum units also three consecutive Bowie-Dick tests, before the sterilizer goes back into routine use. Our spore-testing guide walks through it.

Is this a validation or calibration certificate?

No. We check and document that the unit reaches and holds its settings on full cycles. We do not issue accredited calibration certificates; if your facility needs one, tell us and we will say plainly whether we can help.

Southern California pickup

Book a pickup

Tell us the model, the error on the screen and what it does. A technician reads it and texts you back with a price range and the next pickup day in your area.

  • Pickup, bench diagnostic and return — $125, credited toward the repair
  • A tested loaner swapped in on the same stop, from $149 — free on repairs over $900
  • A written quote before any work starts
  • Typical bench time: 3 to 5 business days on the bench, parts permitting

Rather talk? Call or text (424) 622-8416.