Autoclave testing after repair
A repaired sterilizer has to prove it works before it goes back into service. We run every unit through full cycles on the bench with temperature and pressure checked against its settings, and you get the record for your log.
What we check before a unit leaves
- Full cycles of the types you use, with chamber temperature and pressure checked against the unit's own settings.
- Door seal, drying and the end-of-cycle venting.
- Water level and fill on automatic units; vacuum performance on Class B units.
- The cycle printout or data log, sent back with the unit.
What it does, what failed, what it costs
| Symptom | Usual cause | What we do | Price |
|---|---|---|---|
| Failed spore test with no error on the screen | Chamber not reaching or holding sterilizing temperature: sensor drift, a weak heater, air trapped by a leak, overloading | Temperature and pressure logged through full cycles, fault traced and repaired, retested | from $125 |
| Indicator strips not changing fully | Low temperature, short exposure time, wrong cycle for the load, or wet packs | Cycle verified against the unit settings, cause found and quoted | from $125 |
| Unit back from a repair elsewhere, no paperwork | Repair not documented | Full cycles with a logged temperature and pressure check, printout for your file | from $125 |
Prices are "from", with labor, ordinary parts and a test cycle. The final price comes after the bench diagnostic, and nothing is done until you approve it. All prices →
Related
Spore testing in California
How often, what to log and what to do after a repair.
Bowie-Dick test
What it proves, which autoclaves need it and which do not.
Preventive maintenance
Gaskets, filters, cleaning and a test cycle before something fails.
Dental offices
Weekly spore tests, a loaner, and repairs that keep the chair schedule.
Tattoo and piercing studios
Body-art rules and a sterilizer that has to work every day.
What the price includes
- Pickup and return anywhere in our Southern California area, the bench diagnostic and a written quote — $125, credited toward the repair.
- After the repair: full cycles on the bench with a temperature and pressure check, the printout or log kept for your records.
- A loaner on the same stop if you need one — from $149, free on repairs over $900.
- 90-day warranty on repairs, 1 year on overhauls.
Questions
Do you spore-test the unit after a repair?
We run full cycles on the bench with chamber temperature and pressure checked against the unit settings, and we include the printout. The biological indicator that counts for your log is the one you run in your own office on your first loads back — the CDC recommends confirming a sterilizer with biological indicators after a major repair before it returns to use.
What does the CDC say to do after a major repair?
Run biological indicators in three consecutive empty cycles, and on pre-vacuum units also three consecutive Bowie-Dick tests, before the sterilizer goes back into routine use. Our spore-testing guide walks through it.
Is this a validation or calibration certificate?
No. We check and document that the unit reaches and holds its settings on full cycles. We do not issue accredited calibration certificates; if your facility needs one, tell us and we will say plainly whether we can help.
Book a pickup
Tell us the model, the error on the screen and what it does. A technician reads it and texts you back with a price range and the next pickup day in your area.
- Pickup, bench diagnostic and return — $125, credited toward the repair
- A tested loaner swapped in on the same stop, from $149 — free on repairs over $900
- A written quote before any work starts
- Typical bench time: 3 to 5 business days on the bench, parts permitting
Rather talk? Call or text (424) 622-8416.